Page 99 - 诺霸英文2022
P. 99

TORQUE MEASUREMENT



        SPARES FOR INSTRUMENTATION PRODUCTS                   PART NUMBER SUFFIX SYSTEM






        8     SPARES FOR INSTRUMENTATION PRODUCTS             Transducers can be ordered for use with Norbar’s current range
        38876 Rechargeable Battery Pack for Pro-Log, TST & TTT  of instruments (TST, TTT, TTL-HE and T-Box™ 2), and as Industry
        29610  1 ∕ 4" Female -  ∕ 2" Male Sleeve Adaptor      Standard (mV/V calibrated) for certain display instruments from other
                      1
                                                              manufacturers.
        29611  1 ∕ 2" Female -  ∕ 4" Male Sleeve Adaptor      A part number suffix system is used to identify the type of calibration
                      3
        29612  1 ∕ 2" Female - 1" Male Sleeve Adaptor         required. For example, a 1,000 N�m Static Transducer for use with a
        29613  3 ∕ 4" Female - 1" Male Sleeve Adaptor         TTT instrument would become part number 50772.LOG.
        29614  3 ∕ 8" Female -  ∕ 2" Male Sleeve Adaptor
                      1
                                                               SUFFIX  USAGE                         CERTIFIED IN
        4     SERIAL DATA LEAD KIT                             �LOG
        60248 Serial Data Lead Kit                             �IND   TST, TTT, TTL-HE & T-Box™ 2    Torque Units
                                                                                                     mV/V
                                                                      Instruments of non Norbar manufacture
        Note: Serial Data Lead Kit is not suitable for use with HE Instrument and   (check with Norbar for suitability)
        TruCheck™ 2
                                                                      and TST, TTT, TTL-HE & T-Box™ 2
        60259 USB to Serial Data Lead (Does not work with USM)  Where the transducer suffix .LOG is used, the transducer is calibrated with
        This kit enables Norbar 'CE Marked' instruments (Post January 1996 ETS, TWA   an instrument, as a system, a calibration certificate is provided in torque
        and DTS plus all Pro-Test, TST and TTT) to connect to most PCs.  units. A full scale mV/V figure is also supplied.


        STATIC TRANSDUCER BENCH STANDS







        4           BENCH STANDS FOR STATIC TORQUE TRANSDUCERS  Bench stands ensure the correct mounting of Norbar's Static Torque
        50211       Small frame size (10 N�m)  ∕ 4" sq�       Transducers up to 7,000 N�m (5,000 lbf�ft).
                                     1
        50212       Small frame size (50 N�m)  ∕ 8" sq�
                                     3
        50213       Small frame size (100/250 N�m)  ∕ 2" sq�
                                         1
        50220       Large frame size (250/500 N�m)  ∕ 4" sq�
                                         3
        50221       Large frame size (1,000/1,500 N�m) 1" sq.
        50127.BLK9005* Extra large size (7,000 N�m) 1 ∕ 2" sq�
                                       1
        52014       1 ∕ 4" Insert for Small Bench Stands
        52015       3 ∕ 8" Insert for Small Bench Stands
        52016       1 ∕ 2" Insert for Small Bench Stands
        52017       3 ∕ 4" Insert for Large Bench Stands
        52018       1" Insert for Large Bench Stands

        * Dimensions available on request














                       Small    Large
         Model
                     Frame Size  Frame Size
                      50211
         Part Number  50212   50220
                              50221
                      50213
                  A    50      70
         Dimensions
         (mm)     B    99      120
                  C    92      150
         Weight (kg)   0�8     2.5


                                         enquiry@norbar�com | www�norbar�com                                        98