Page 108 - 诺霸英文2022
P. 108
TORQUE MEASUREMENT
Calibration details
ANNULAR TRANSDUCERS
4 ANNULAR TRANSDUCERS FOR 72 mm SERIES GEARBOX 4 ANNULAR TRANSDUCERS FOR PTS/PTM 72
(HT & PT) (Not suitable for PTS/PTM tools) Suitable for PTS/PTM-72 mm Series
Suitable for PT-72 mm Remote Series and HT-72 50840.xxx 100 - 1,000 N�m
50666.xxx 100 - 1,000 N�m 50841.xxx 150 - 1,500 N�m
50667.xxx 150 - 1,500 N�m 50842.xxx 200 - 2,000 N�m
50668.xxx 200 - 2,000 N�m 50846�LOGA 100 - 1,000 N�m with Angle
Standard calibration is performed loading counter-clockwise only.
Annular Annular
Transducers Transducers
Model for use with for use with
72 mm Series 72 mm Series
Multipliers Multipliers
50666.xxx
50667.xxx
Part 50668.xxx 50846.LOGA
Number 50840.xxx
50841.xxx
50842.xxx
Dimensions (mm) A B 58 85
84
93
73
ØC
Weight (kg) 72 3�1
1.5
Torque and Angle Annular Transducer Note:
• 5,000 N�m and above include dowels on both mounting faces 4 ANNULAR TRANSDUCERS
• Angle resolution < 1° when used with T-Box™ 2 SECCAL�CW Secondary calibration in one direction on annular
• CW+CCW calibration is standard transducers for HT/PT9 & HT/PT11 to extend the
range below 10% of the rated capacity, when
• Use 60308.xxx series lead for direct connection to T-Box™ 2 for torque ordered with new unit
and angle/turns monitoring and storage SECCAL�CW+CCW Secondary calibration in two directions on annular
• PT square drive and other parts may require removal to fit transducer transducers for HT/PT9 & HT/PT11 to extend the
• All the above are standard construction� Harsh Environment models are range below 10% of the rated capacity, when
available on request ordered with new unit
'
• �INDA' versions are available on request ADDCALPOINTS�NEW Additional calibration steps below 10% of rated
capacity to 2% for transducers up to 7,000 N�m
(5,000 lbf�ft) when ordered with new unit
Note: PTS™ and reactions with dowel holes can be supplied at an extra
cost on request� Request details on PneuTorque® Type '�XD'
TRANSDUCER LEADS
If ordering a static, annular or rotary transducer you will also require a corresponding lead (see list
below)�
To comply with the latest calibration standards, most new transducer leads will have a suffix to indicate
the length in centimetres.
4 TRANSDUCER LEADS 4 TRANSDUCER LEADS
60216�200 PRO-LOG, TST, TTT, T-Box XL & T-Box 2 to 10 Way Transducer 60308�400 PRO-LOG, TST, TTT, T-Box XL & T-Box 2 to
for use with Norbar Rotary Transducers Torque & Angle Annular Transducers
60217�200 PRO-LOG, TST, TTT, T-Box XL & T-Box 2 to 6 Way Transducer 60308�600 PRO-LOG, TST, TTT, T-Box XL & T-Box 2 to
for use with Norbar Static & Annular Transducers Torque & Angle Annular Transducers
60223�200 PRO-LOG, TST, TTT, T-Box XL & T-Box 2 to no connector 60308�1000 PRO-LOG, TST & TTT to
60224�200 10 Way Transducer to no connector Torque & Angle Annular Transducers
60225�200 6 Way Transducer to no connector Other lengths can be ordered at an additional cost.
51067�225 ETS to Transducer (Pre 1994) + 5 way (60055) Note: The system should be calibrated with the increased length lead, as
60152�225 ETS to Transducer (Post 1994) + 5 way (60163) calibration may be affected.
Note: The maximum permissible cable length is 15 m for TST, TTT or
T-Box™ 2 and 7 m with a T-Box™ XL. Contact Norbar for further
details�
107 enquiry@norbar�com | www�norbar�com