Page 291 - Mahr马尔量具完整
P. 291

Millimar EMD-832P-48-W1 / EMD-832P-48-W2

        Electronic Levels - Differential Level System


        FEATURES

        •  Compare the orientation attitude
          of separate or adjacent    Application:
          horizontal surfaces
        •  Level systems are angular-linear   •  Used to determine any deviation in
          compatible                the right angle relationship between
        •  Sensing heads are interchange-  a horizontal surface and the earth’s
          able with Federal electrical   gravitational force (usually expressed
          spec.‘s gageheads to accommo-  as an angular or linear deviation from
          date linear measurements  absolute level)
        •  Fast response: quick response to
          slight angular changes per-  TECHNICAL DATA
          mit taking fast and accurate
          measurements at various sensing   Order no.                   2120550                   2120551
          head positions or taking dynamic   Product type            EMD-832P-48-W1            EMD-832P-48-W2
          position readings        Range of digital display  µm                   ± 2000, ± 200, ± 20
        •  Resolution/Repeatability: Mahr   Range of digital display  inch      ± .100“, ± .010“, ± .001“
          Federal’s Electronic Levels far ex-  Range of digital display  arcsec  ± 1000 arcsec, ± 200 arcsec
          ceed the sensitivity and accuracy   Range of digital display  rad       ± 1 mrad, ± 5 mrad
          of precision spirit levels with a   Resolution  µm                        1, 0.1, 0.02
          resolution to 6 μin per foot
          (.1 arc second), compared to the   Resolution  inch                  .0001“, .00001“, .000001“
          spirit level’s resolution of .0001“   Resolution  arcsec                0.1 arcsec, 1 arcsec
          per foot. With repeatability at   Resolution   rad                    0.005 mrad, 0.0005 mrad
          ±.1 arc second, Electronic Levels   Graduation value  arcsec                50, 10
          are ideal for ultra-high resolution   Tolerance display      LED 5 cllass               LED 5 class
          profiling.               Probe inputs                                         2
        •  Direct dimensional readout:   Compatibility                                Federal
          multiplier feature permits
          operator to view displacement   Dynamic functions                      Max, Min, TIR, Nominal
          caused by the angular measure-  Classification                                5
          ment of the level head; this is   Data interface                            RS232C
          displayed as an inches per foot   Control inputs                              3
          readout rather than arc seconds;   Control outputs                            5
          eliminates readout confusion   Analog output                                ±5VDC
          when switching from spirit levels   Energy supply     Rechargeable battery, 10 h at full load   Battery operation, 230 V / 50 Hz
          to electronic levels                                 or 120 VAC/240 VAC 50-60 Hz via AC
        •  Angular-linear compatible: sens-                              adapter
          ing heads are easily interchange-  Power supply connection     120 VAC 50/60Hz      220 VAC 50/60Hz (EU)
          able with Federal electrical   Compatibility                                Federal
          spec.‘s gageheads to accommo-
          date linear measurements
        •  Electronic levels are much easier   ACCESSORIES
          to use with an autocollimator or   Order no.  Product name           Compatibility  Product type
          a laser based calibration system
        •  Performance is comparable and   2120373  Electronic level gagehead with 2.5 m / 8 ft cable  Federal  EGH-2013-W1
          results are obtained without time   2120374  Electronic level gagehead with 6 m / 20 ft cable  Federal  EGH-2013-W2
          consuming sight path align-  2120363  Surface plate certification software       EDD-1035
          ments, cleaning of sensitive op-  2120292  Adjustable leveling foot              EAT-1029
          tical surfaces or hard to control   2120293  Magnetic base                       EAT-1054      EAT-1054
          environmental conditions  2120294  Vee base 120° (102 mm / 4“)                   EAT-1055
        •  The differential level system   2120295  Right angle attachment with 120° vee faces (152 mm     EAT-1056
          operates simultaneously with a    / 6“)
          single amplifier, permitting an   2120296  Adjustable 3-pad base (50 – 203 mm / 2 – 8“)     EAT-1057
          immediate comparison between   2120297  3-pad base (50 mm / 2“)                  EAT-1058
          two surfaces             2120298  3-pad base (102 mm / 4“)                       EAT-1059
        •  Adjustable bases permit setup on   2120299  3-pad base (152 mm / 6“)            EAT-1060
          surfaces that are out-of-level or   2120300  Base (l= 320 mm / 12.625“) with integrated 120° vee     EAT-1061
          square by as much as ± 1.5°       ground base                                                  EAT-1062
        •  Package contains: indicating   2120301  Spindle block (l= 19 mm / .750“)        EAT-1062
          instrument 832 F, 2 electronic
          level heads EGH-2103-W2 with
          6m/20ft cable, 2 adjustable
          mounts EAT-1029, remote data
          entry handswitch with 6m/20ft
          cable, power source, instruction
          manual, case
                                     EAT-1055     EAT-1056      EAT-1057      EAT-1058;     EAT-1061   EAT-1029;
                                                                              EAT-1059;                EGH-2013-W1;
                                                                              EAT-1060                 EGH-2013-W2