Page 256 - Mahr马尔量具完整
P. 256

Millimar N 1702 M / N 1704 M / N 1704 T / N 1704 U

       Module for Inductive Probes


       FEATURES

       •  Flexibly configurable
        RS-485
        bus modules
       •  Powerful connection modules for
        evaluating measuring sensors
        (inductive/pneumatic)
       •  Synchronous data retrieval from                    Application:
        multiple connected measuring
        probes                                               Smart and flexible combination of measuring modules and software for
       •  Connection of N 1700 modules                       solving customer-specific measuring tasks.
        via USB interface to the smart,
        universal evaluation and configu-  TECHNICAL DATA
        ration software Millimar Cockpit
       •  Connects all compatible probe   Order no.                  5331120     5331140    5331141     5331142
        types using one module   Product type                        N 1702 M   N 1704 M    N 1704 T    N 1704 U
       •  Flexible and modular product com-  Storage temperature MAX  °C                60
        binations to tackle customer-specific   Resolution   µm                         0.1
        measuring tasks          Measuring range, inductive probe  µm          ± 2000, ± 5000, ± 1000, ± 500
       •  Maximum theoretical bus data   Probe inputs                  2                       4
        rate of 4189 values/s (depending
                                                                                Mahr, Mahr
                                                                    Mahr, Mahr
        on the number of connected   Compatibility                  1340, Mahr   half-bridge, Mahr   Tesa  Marposs
        channels)                                                 half-bridge, Mahr LVDT, Mahr VLDT
       •  Package contains:                                       LVDT, Mahr VLDT
        instruction manual       Configuration                                   Millimar Cockpit Software
                                 Data transmission rate      Hz                         4189
                                 Error limit                                       0.3 % (min. 0.2 μm)
                                 Temperature coefficient   µm/°C                        0.02
                                 Data interface                                        RS485
                                 Energy supply                                    + 5V from N 1700 Bus
                                 IP protection category                                 IP 42

                                  Order no.   Depth          Height        Width
                                               mm             mm            mm
                                 5331120        66            54.8           77
                                 5331140        66            54.8          116.5
                                 5331141        66            54.8          116.5
                                 5331142        66            54.8          116.5







































      252                         Millimar | Electrical Length Measuring Instruments
   251   252   253   254   255   256   257   258   259   260   261